ViCare U7

The first fully-integrated life support platform that combines environmental control, infusion, monitoring and video surveillance. Oxygen therapy, temperature control and fluid management help stabilize critically ill animals. Real-time electronic monitoring and live streaming video ensure continuous evaluation of patient status. Moreover, clinical monitoring is linked to environmental parameters to adapt conditions to the patient needs and ensure a "Complete ICU Care in One Cabin".

4 Major Functions in One Cabin

O2

CO2

Humidity

Temperature

1 Smart Environment Control

Smart Adjustment Prompts

Real-time tracking of animals' physiological vital signs inside the cabin to guide environmental parameter setting

2 Wireless Monitoring

Real-time Monitoring

Infusion Progress

65%

Flow Rate

54 ml/h

ICU Cabin Infusion Pump
3 Integrated Infusion Therapy
4 Video Surveillance

Camera

3 Intensive Therapies in One Cabin

Oxygen Therapy

Clinical Recommended Oxygen Concentration
  • Initial Emergency Treatment: 90% - 100%
  • Severe Hypoxemia (SpO2 < 90%) : >50%
  • Mild Hypoxemia (SpO2 < 94%) : 30% - 40%
Fast Oxygen Mode

Raise the oxygen concentration inside the cabin to 40% within 2 minutes.

90% High-concentration Output

Suitable for rapid oxygen support in emergency patients, meeting oxygen therapy needs of various patient conditions.

Oxygen-saving

Oxygen supply automatically pauses when the door is opened and instantly resumes once closed, reducing oxygen consumption.

Open Door

Close Door

SpO2-linked Oxygen Control
  • Real-time tracking of blood saturation
  • One click adjustment of target O2 concentration

Smart Adjustment Prompts

Detect patient SpO2 <95%, recommend adjusting oxygen concentration to 50%

Adjust Immediately
Ignore

Temperature Therapy

Air conditioning, floor heating & ambient air heating, a triple temperature control for all scenarios.

Air Conditioning

Floor Heating/Cooling

Ambient Air Heating

Smart Linked Temperature Control Technology
  • Real-time tracking of animal body temperature
  • One click adjustment of target environmental temperature

Smart Adjustment Prompts

When the patient's body temperature is detected below 36.7°C, it is recommended to set air temperature to 28°C and floor temperature to 28°C.

Adjust Immediately
Ignore

Infusion Therapy

Hypothermia is a common complication of anesthesia and a frequent condition in critically ill patients. Warming infused fluids help restore body heat and maintain animal's temperature. Active core rewarming via fluid warming is recommended when body temperature is below 33°C.

Built-in infusion pump reduces clutter from scattered IV set

Smart heating adjusts temperature with infusion rate for steady infusion temperature

2 Layers of Patient Monitoring in One Cabin

  • Anesthesia-related deaths occur in the post-operative period in 47% and 60% of dogs and cats respectively, with the majority happening within the first 3 hours.
  • Intensive care requires continuous monitoring of patients' physiological parameters, such as HR/RR, SpO₂, blood pressure and body temperature, which is also necessary for critically ill patients with little to no mobility.

1Wireless Monitoring

Modular design, different modules meet different clinical scenario requirements

Free from cable constraints, facilitating out-of-chamber care by medical staff

Wearable design easy to put on and off

Accurate Measurement

Animal-specific anti-motion and weak signal detection algorithms provide accurate monitoring and measurement for veterinary hospitals. Support to continuous measurement of body temperature, HR, NIBP, SpO2, ECG.

NIBP

Animal-specific algorithms; weak signal detection method, anti-interference technology

Weak signal detection

Weak signal amplification

SpO2

Anti-low perfusion, anti-motion technology

Pulse rate as adaptive filter factor
Adaptive smoothing filtering
ECG

CrozFusion™

Intelligent multi-parameter fusion

2Video Surveillance

  • Integrated camera enables remote viewing
  • Patient can be left undisturbed with the help of curtains, while maintaining surveillance

1 System for Centralised Management

Supports connection to the VetiNet CMS central monitoring system, enabling veterinarians and nurses to view animals' physiological signs, status and trend changes in real time via connected desktop computers and mobile devices.

Amazing Design Details Throughout

High-temperature Vaporized Humidification

Same design as NICU incubators

Industry-first high-temperature steam sterilization technology, with incubator-grade design, suppresses bacterial growth and limescale buildup at the source.

ViAir Circulation Control Technology

Large-capacity soda lime canister & air duct design for efficient CO₂ elimination.

ViCare U7 Internal Gas Distribution

In-cabin air circulation ensures uniform gas distribution and prevents CO₂ buildup at the bottom.

Caring Ambient Lighting

Red & white light auto switch on a timer

Auto-switching between red and white lighting does not disrupt animals' circadian rhythms, supporting recovery.

Intuitive Design

4-level Care Indicator Light

Clear at a Glance

Intensive Care
Level 1 Care
Level 2 Care
Level 3 Care
Capacitive Touch Screen
Electric Suction Door

Hands-free Operation

Operation Window

Supports Two-handed Manipulations

Safeguard Design

Contact Us

If you're interested in our products or service, you can choose to leave your information here, and we will be in touch with you shortly.
Verification code
By submitting the information above, I have read and agreed to the Privacy Policy *
Please check if you'd like to subscribe to Mindray Animal Medical's Newsletters
Mindray respects your privacy. We use cookies for a variety of purposes, such as website functionality, improving your experience of our website, building integration with social media and helping target our advertising. By continuing your visit on our website, you are consenting to our use of cookies. However, you can change your cookie settings at any time.

close